Ella: Your Next Generation ELISA

CE marked to the IVD Regulation (EU 2017/746), the Ella platform brings its speed, automation, and reproducibility into the clinical laboratory. With minimal training, Ella delivers accurate and reliable results, streamlining workflows, and accelerating clinical decision making. Ella’s combination of performance and automated workflow brings your immunoassays to the next level. In less than 90 minutes you get highly reproducible assay data and consistent biomarker detection with minimal hands-on time. The assay performance behind that data includes sub-picogram level sensitivity, 4+ logs of dynamic range, and precision that rivals the best laboratory automation. All in a compact package that doesn’t break your budget and fits on your benchtop. Important Note: Simple Plex assays (cartridges and panels) used on the Ella instrument are currently available for Research Use Only (RUO) and not for human or animal therapeutic or diagnostic use.

Key Benefits for Clinical Labs

  • CE-IVD marked as per EU IVDR Class A Requirements – Supporting clinical adoption and patient testing
  • Fast, Actionable Results – Fully analyzed, quantitative data in 90 minutes
  • Minimal Hands-On Time – Only 10-15 minutes of manual labor required
  • Standardized, Reproducible Results – Automated microfluidics eliminates variability and support consistency across operators and sites
  • Low Sample Volume – Requires only 25 µL, preserving precious patient samples
  • Highly sensitive with a broad dynamic range – Achieves sub-picogram detection limits and over four log dynamic range, suitable for low-abundance biomarkers
  • Fully Automated – Cartridges come pre-loaded with all reagents – including calibration curves – streamlining workflow and eliminating manual pipetting errors. Results are consistent across operations and labs.

Why consider Ella CE-IVD?

 

  • Reliable Results from Any Operator or Site – Fully automated microfluidic cartridges ensure consistent, transferable performance.
  • Optimize Sample Use and Reduce Costs – Low sample volume requirements and built-in calibration save both reagents and time
  • Scale Efficiently Across Research Areas – Supports up to 8 analytes simultaneously, with a comprehensive menu of over 300 fully validated assays

Citations for Ella Automated Immunoassay System CE-IVD

View all citations for the Simple Plex platform.
Please visit our Instrument Citation Database to search our collection of scientific articles that feature our instruments.

Testimonials from your Peers for Simple Plex

Showing  1 - 5 of 10 testimonials Showing All

"We needed assays that were not only excellent at conserving our limited sample volumes but would allow us to test a lot of markers quickly and efficiently. The Luminex and Simple Plex assays proved to be the ideal choice in this case, giving us a level of accuracy and reproducibility that we’ve been unable to get with other platforms."

Dr. Melissa Munroe, M.D., Ph.D., Research Associate, Oklahoma Medical Research Foundation (OMRF)

"Simple Plex assays on Ella gave us speed and efficiency so we could complete our assays quickly, and the high quality of the data meant that we could easily see differences between disease state samples and controls. Plus, sample preparation was so simple it reduced chances of errors significantly."

Paulomi Aldo, Research Associate and Reproductive Sciences Core Manager, Department of Obstetrics, Gynecology and Reproductive Sciences, Yale University

"Ella allows for reproducible sample data with minimal sample input. The lower volume usage allows for the expansion of research into novel areas of angiogenesis and inflammation as they pertain to many forms of cancer."

Andrew Nixon Ph.D., M.B.A.,, Associate Professor, Medicine & Director, Duke University

Showing  1 - 5 of 10 testimonials Showing All

More Information About Ella Automated Immunoassay System CE-IVD

Simple Plex Technology

Ella does immunoassays in a microfluidic Simple Plex cartridge. It's like using a pre-kitted immunoassay, except everything's pre-loaded on the cartridge—even the calibration curve! All you need to do is add your sample and buffers and put the cartridge in Ella.

The immunoassay part works like this: sample runs through a microfluidic channel that binds your protein of interest. Next, Ella washes off unbound analyte and adds a detection reagent. Because each channel has three Glass Nano Reactors (GNRs) coated with a capture antibody, you get triplicate answers for each sample. Answers are then generated from the factory-calibrated standard curve that comes with every cartridge. Sound familiar? It's the same immunoassay you're used to, just without the errors that come with traditional assays.

Simple Plex multiplex diagram
  1. Sample is routed through microfluidic channels.
  2. Capture antibody captures target analyte.
  3. Stringent wash removes unbound analyte.
  4. Detection antibody migrates through microfluidic channel.
  5. Stringent wash removes unbound detection antibody.
  6. Scan GNRs. 

Simple Plex Applications

sars cov-2 virus

COVID-19 Research

Quantify cytokine and pro-inflammatory responses to SARS-CoV-2 infection in 90 minutes using an automated, multianalyte format.

joint inflammation

Inflammation Research

Simple Plex assays enable rapid and reproducible quantification of inflammatory responses such as cytokine release syndrome and sepsis. 

immune cells attack cancer cell

Cancer Biomarker Research

Simple Plex assays for cancer research have the sensitivity to profile low abundance cancer biomarkers.

neuronal network

Neuroscience Research

Measure key neuroscience biomarkers such as neurofilament light (NF-L) and neurofilament heavy (NF-H) in CSF, plasma, and serum.

Cell and gene therapy

Cell Therapy Research and Development

The Simple Plex HEK 293 HCP 3G assay on the Ella platform offers broad detection coverage of this host cell protein (HCP).

protein bioprocessing workflow

Bioprocess Testing

Iterate your workflow faster with Simple Plex CHO HCP 3G-1 assays for process-related impurity testing.

preclinical scientist pipetting in the lab

Preclinical Research

With a four-log range of detection, Simple Plex assays have the sensitivity to pick up even very low picogram-per-milliliter levels of endogenous mouse or rat analytes.

AAV2 virus for simple plex

Viral Titer Assays

Get highly reproducible adeno-associated virus and lentivirus titer data with no manual steps in just 90 minutes.

Description Single Plex Specification Multianalyte Specification Multiplex Specification Customizable Specification
Sample Volume Required 2.5-25 µL 2.5-25 µL 2.5-25 µL 2.5-25 µL
Dynamic range 3-4 logs
Sensitivity <1pg/mL (assay dependent)
Assay Runtime 75 Minutes 80 Minutes
Samples per run Up to 72 Up to 32 Up to 32 Up to 48
Plex level 1 Up to 4 Up to 8 1
Results per run Up to 72 Up to 128 Up to 256 Up to 48
Replicates per result Triplicate Triplicate Duplicate Triplicate
Ella Weight 16 kg (35.3 lbs)
Ella Dimensions (closed) 37 cm W x 54 cm D x 26 cm H
Ella Power 100-240 V(AC), 300 VA, 45/65 Hz, Class I Installation Category(Over Voltage) II
Ella Operating temperature 15 to 30 °C (59° to 86°F)
Ella Operating humidity 15-80% relative, non-condensing