Glucagon Quantikine ELISA Kit Best Seller
R&D Systems, part of Bio-Techne | Catalog # DGCG0
Key Product Details
Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (50 µL), Serum (50 µL), EDTA Plasma (50 µL), Heparin Plasma (50 µL)
Sensitivity
14.7 pg/mL
Assay Range
31.3-2000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma)
Product Summary for Glucagon Quantikine ELISA Kit
The Quantikine Glucagon Immunoassay is a 4.5 hour solid-phase ELISA designed to measure Glucagon in cell culture supernates, serum, and plasma. It contains natural porcine Glucagon as the standard. The antibodies were raised against a human Glucagon synthetic peptide. This immunoassay has been shown to accurately quantitate human, mouse, rat, and porcine Glucagon.
Product Specifications
Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Measurement
Quantitative ELISA
Detection Method
Colorimetric - 450nm (TMB)
Conjugate
HRP
Reactivity
Multi-Species
Specificity
Natural Glucagon. This assay cross-reacts <12% with Oxyntomodulin.
Cross-reactivity
Cross-reactivity observed with 1 or more available related molecules. Cross-species reactivity observed with 1 or more species tested.
Interference
No significant interference observed with available related molecules.
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.
Cell Culture Supernates, EDTA Plasma, Heparin Plasma, Serum
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 20 | 20 | 20 |
| Mean (pg/mL) | 315 | 618 | 1024 | 354 | 653 | 1080 |
| Standard Deviation | 10.3 | 22.0 | 27.6 | 30.7 | 37.8 | 63.6 |
| CV% | 3.3 | 3.6 | 2.7 | 8.7 | 5.8 | 5.9 |
Recovery for Glucagon Quantikine ELISA Kit
The recovery of Glucagon spiked to levels throughout the range of the assay in various matrices was evaluated.
| Sample Type | Average % Recovery | Range % |
|---|---|---|
| Cell Culture Media (n=4) | 98 | 91-108 |
| Human EDTA Plasma (n=4) | 98 | 86-107 |
| Human Heparin Plasma (n=4) | 96 | 88-100 |
| Human Serum (n=4) | 102 | 95-111 |
| Mouse Serum (n=2) | 99 | 92-106 |
| Porcine Serum (n=2) | 97 | 91-107 |
| Rat Serum (n=1) | 93 | 86-101 |
Linearity
To assess the linearity of the assay, samples spiked with high concentrations of Glucagon were serially diluted with Calibrator Diluent to produce samples with values within the dynamic range of the assay.
Scientific Data Images for Glucagon Quantikine ELISA Kit
Multi-species Glucagon ELISA Standard Curve
Preparation and Storage
Shipping
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage
Store the unopened product at 2 - 8 °C. Do not use past expiration date.
Background: Glucagon
In normal metabolism, Glucagon is secreted in response to
low blood glucose (hypoglycemia) and downregulated in response to high blood
glucose (hyperglycemia). Although Glucagon binding sites are found in liver,
brain, pancreas, kidney, intestine, and adipose tissue, the main activity of
Glucagon receptors occurs in the liver, where Glucagon stimulates
gluconeogenesis and glycogenolysis, thereby increasing blood glucose (1-4). It
is particularly important that the brain receive sufficient glucose, since it
is unable to store more than a minute quantity. Therefore the release of
Glucagon from alpha-cells is under control by both hormones and neurotransmitters,
and is very responsive to circulating glucose concentration. Insulin, and/or
the zinc that islet beta cells secrete with it, downregulates Glucagon secretion
in intact islets (5, 6). Glucagon secretion is also downregulated by the
neurotransmitter gamma-aminobutyric acid (GABA), somatostatin produced by islet
delta-cells, and GLP-1, but is enhanced by the neurotransmitter L-glutamate, amino
acids (especially arginine), and Glucagon itself (2-4, 7). Through receptors on
the alpha-cells, these substances affect potassium, sodium, and calcium channel
activity and alter intracellular calcium concentration (2-4). Glucose
suppression of Glucagon secretion is probably indirect, acting through
paracrine signals from other islet cells (8).
Like insulin, Glucagon is dysregulated in type 2 diabetes
(T2D) and contributes to its pathology (2-4). Glucagon secretion is less
responsive to insulin-mediated suppression in times of high circulating
glucose, causing glucagonemia, and increasing the risk of hyperglycemia.
Glucagon is also regulated by some of the same messengers that regulate insulin
(10-12). Leptin inhibits alpha-cell glucagon secretion and stimulates beta-cell
insulin secretion, but glucagon blunts the leptin-mediated insulin secretion
(10). Islet alpha-cells express ghrelin receptors and respond to ghrelin by
increasing Glucagon secretion (11). Glucocorticoids, activated by 11 beta-HSD1,
depress Glucagon secretion in hypoglycemia and insulin secretion in
hyperglycemia (12). Although genetic polymorphisms of the Glucagon receptor are
associated with T2D, downregulation of Glucagon secretion or deletion of the Glucagon
receptor in mice that are susceptible to T2D actually improves glycemic control
(13, 14).
Additional Glucagon Products
Product Documents for Glucagon Quantikine ELISA Kit
Product Specific Notices for Glucagon Quantikine ELISA Kit
For research use only
⚠ WARNING: This product can expose you to chemicals including N,N-Dimethylforamide, which is known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.