Skip to main content

Human/Mouse/Rat CD31/PECAM-1 Alexa Fluor™ Plus 555-conjugated Antibody

R&D Systems, part of Bio-Techne | Catalog # AF3628AFP555

Catalog #
Availability
Size / Price
Qty
Loading...
AF3628AFP555-100UG

Key Product Details

Species Reactivity

Human, Mouse, Rat

Applications

Immunohistochemistry, Western Blot, Flow Cytometry, Immunocytochemistry, CyTOF-ready

Label

Alexa Fluor Plus 555 (Excitation = 558 nm, Emission = 572 nm)

Antibody Source

Polyclonal Goat IgG

Product Specifications

Immunogen

Mouse myeloma cell line NS0-derived recombinant mouse CD31/PECAM-1

Specificity

Detects human and mouse CD31/PECAM-1 in direct ELISAs and Western blots. In direct ELISAs and Western blots, approximately 10% cross-reactivity with recombinant porcine CD31 is observed.

Clonality

Polyclonal

Host

Goat

Isotype

IgG

Applications

Application
Recommended Usage

CyTOF-ready

Optimal dilution of this antibody should be experimentally determined.

Flow Cytometry

Optimal dilution of this antibody should be experimentally determined.

Immunocytochemistry

Optimal dilution of this antibody should be experimentally determined.

Immunohistochemistry

Optimal dilution of this antibody should be experimentally determined.

Western Blot

Optimal dilution of this antibody should be experimentally determined.

Formulation, Preparation, and Storage

Formulation

Supplied 0.2 mg/mL in a saline solution containing BSA and Sodium Azide.

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Protect from light. Do not freeze. 12 months from date of receipt, 2 to 8 °C as supplied

Background: CD31/PECAM-1

PECAM-1 (Platelet-Endothelial Cell Adhesion Molecule-1), also known as CD31, is a 130 kDa type I transmembrane glycoprotein adhesion molecule in the immunoglobulin superfamily (1, 2). Expression is restricted to cells involved in circulation, especially endothelial cells, platelets, monocytes, neutrophils and lymphocyte subsets. PECAM-1 is concentrated at cell-cell junctions and is required for Transendothelial Migration (TEM) (1-3). The Extracellular Domain (ECD) of PECAM-1 has ten potential N-linked glycosylation sites and six C2-type Ig-like domains, the first of which is critical for adhesion and extravasation (3, 4). The cytoplasmic domain contains Immunoregulatory Tyrosine-based Inhibitory and Switch Motifs (ITIM, ITSM) that mediate both inhibition and activation via phosphotyrosine-mediated engagement of SH2-containing signaling molecules (1, 5). Metalloproteinase-mediated ectodomain shedding occurs during apoptosis (6) but increased serum PECAM-1 ectodomain in HIV and active multiple sclerosis occurs independent of apoptosis (7, 8). In humans, expression of six isoforms with exon deletions in the cytoplasmic domain is tissue- and stage-specific, but full-length PECAM-1 is predominant. A form lacking the ITSM predominates in mouse (9). Mouse PECAM-1 ECD shows 77%, 63%, 63%, 63%, and 61% amino acid (aa) identity with rat, human, canine, porcine, and bovine PECAM-1, respectively. PECAM-1 participates with other adhesion molecules in some functions, but is the critical molecule for TEM. Homotypic PECAM-1 adhesion in trans, combined with cycling of PECAM-1 to and from surface-connected endothelial cell vesicles, leads leukocytes across endothelial tight junctions (3, 10). Homotypic adhesion and signaling functions also strongly suppress mitochondria-dependent apoptosis (11). In platelets, PECAM-1 is necessary for limiting thrombus formation (12) and promoting integrin-mediated clot retraction and platelet spreading (13), but mechanisms for these phenomena are unclear. PECAM-/- mice are deficient in chemokine-mediated chemotaxis (14).

References

  1. Ilan, N. and J.A. Madri (2003) Curr. Opin. Cell Biol. 15:515.
  2. Xie, Y. and W.A. Muller (1993) Proc. Natl. Acad. Sci. USA 90:5569.
  3. Liao, F. et al. (1997) J. Exp. Med. 185:1349.
  4. Nakada, M.T. et al. (2000) J. Immunol. 164:452.
  5. Chemnitz, J.M. et al. (2004) J. Immunol. 173:945.
  6. Ilan, N. et al. (2001) FASEB J. 15:362.
  7. Eugenin, E.A. et al. (2006) J. Leukoc. Biol. 79:444.
  8. Losy, J. et al. (1999) J. Neuroimmunol. 99:169.
  9. Wang, Y. et al. (2003) Am. J. Physiol. Heart Circ. Physiol. 284:H1008.
  10. Mamdouh, Z. et al. (2003) Nature 421:748.
  11. Gao, C. et al. (2003) Blood 102:169.
  12. Falati, S. et al. (2006) Blood 107:535.
  13. Wee, J.L. and D.E. Jackson (2005) Blood 106:3816.
  14. Wu, Y. et al. (2005) J. Immunol. 175:3484.

Long Name

Platelet Endothelial Cell Adhesion Molecule 1

Alternate Names

CD31, EndoCAM, PECA1, PECAM-1, PECAM1

Entrez Gene IDs

5175 (Human); 18613 (Mouse); 29583 (Rat)

Gene Symbol

PECAM1

UniProt

Additional CD31/PECAM-1 Products

Product Documents

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Note: Certificate of Analysis not available for kit components.

Product Specific Notices


This product is provided under an intellectual property license from Life Technologies Corporation. The transfer of this product is conditioned on the buyer using the purchased product solely in research conducted by the buyer, excluding contract research or any fee for service research, and the buyer must not (1) use this product or its components for (a) diagnostic, therapeutic or prophylactic purposes; (b) testing, analysis or screening services, or information in return for compensation on a per-test basis; or (c) manufacturing or quality assurance or quality control, and/or (2) sell or transfer this product or its components for resale, whether or not resold for use in research. For information on purchasing a license to this product for purposes other than as described above, contact Life Technologies Corporation, 5781 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@thermofisher.com.

For research use only

Loading...
Loading...
Loading...
Loading...
Loading...
Loading...