Skip to main content

GLI-1 Antibody [Alexa Fluor™ Plus 680]

Novus Biologicals, part of Bio-Techne | Catalog # NB600-600AFP680

Novus Biologicals, part of Bio-Techne
Catalog #
Availability
Size / Price
Qty
Loading...
NB600-600AFP680
Forumulation
Catalog #

Key Product Details

Species Reactivity

Human, Mouse, Canine

Applications

Immunohistochemistry, Immunohistochemistry-Paraffin, Western Blot, Immunoblotting, ELISA, Flow (Intracellular), Immunocytochemistry/ Immunofluorescence, Chromatin Immunoprecipitation (ChIP), Knockdown Validated

Label

Alexa Fluor Plus 680

Antibody Source

Polyclonal Rabbit IgG

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Product Specifications

Immunogen

A synthetic peptide made toward the C-terminus portion of the human GLI-1 protein (between residues 800-850)

Reactivity Notes

Canine reactivity reported from a verified customer review.

Localization

Cytoplasmic and Nuclear

Specificity

No reaction occurs with human or mouse Gli2 or Gli3.

Clonality

Polyclonal

Host

Rabbit

Isotype

IgG

Applications for GLI-1 Antibody [Alexa Fluor™ Plus 680]

Application
Recommended Usage

Chromatin Immunoprecipitation (ChIP)

Optimal dilutions of this antibody should be experimentally determined.

ELISA

Optimal dilutions of this antibody should be experimentally determined.

Flow (Intracellular)

Optimal dilutions of this antibody should be experimentally determined.

Immunoblotting

Optimal dilutions of this antibody should be experimentally determined.

Immunocytochemistry/ Immunofluorescence

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry-Paraffin

Optimal dilutions of this antibody should be experimentally determined.

Knockdown Validated

Optimal dilutions of this antibody should be experimentally determined.

Western Blot

Optimal dilutions of this antibody should be experimentally determined.
Application Notes
Optimal dilution of this antibody should be experimentally determined.

Formulation, Preparation, and Storage

Purification

Immunogen affinity purified

Formulation

50mM Sodium Borate

Preservative

0.05% Sodium Azide

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store at 4C in the dark.

Background: GLI-1

Gli1 was produced against a peptide corresponding to the carboxy-terminal region of the mouse Gli-1 protein. This region is not conserved among other gli family members, namely Gli-2 and Gli-3. Gli was termed by Kinzler et al. (1987) as 'glioma-associated oncogene' amplified in malignant gliomas. Analysis of the cloned gene demonstrates that the gene contains 5 repeats of zinc-finger sequences, which places gli in the family of Kruppel (Kr) zinc finger proteins. Northern analysis reveals that GLI is expressed in embryonal carcinoma cells but not in most adult tissue. GLI has been localized to 12q13-q14.3 by Southern blot analysis. On mouse the gene is located on chromosome 10. In mice, 3 zinc finger transcription factors, Gli-1, Gl-i2 and Gli-3, have been implicated in the transduction of Sonic hedgehog (Shh) signal. In papillary epithelium, shh, gli1 and ptc all follow similar expression patterns. Gli1 expression is central and probably sufficient for tumor development in humans.

Long Name

Glioma-Associated Oncogene Homolog 1 [Zinc Finger Protein]

Alternate Names

GLI1

Gene Symbol

GLI1

Additional GLI-1 Products

Product Documents for GLI-1 Antibody [Alexa Fluor™ Plus 680]

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Product Specific Notices for GLI-1 Antibody [Alexa Fluor™ Plus 680]



This product is provided under an intellectual property license from Life Technologies Corporation. The transfer of this product is conditioned on the buyer using the purchased product solely in research conducted by the buyer, excluding contract research or any fee for service research, and the buyer must not (1) use this product or its components for (a) diagnostic, therapeutic or prophylactic purposes; (b) testing, analysis or screening services, or information in return for compensation on a per-test basis; or (c) manufacturing or quality assurance or quality control, and/or (2) sell or transfer this product or its components for resale, whether or not resold for use in research. For information on purchasing a license to this product for purposes other than as described above, contact Life Technologies Corporation, 5781 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@thermofisher.com. This conjugate is made on demand. Actual recovery may vary from the stated volume of this product. The volume will be greater than or equal to the unit size stated on the datasheet.

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.

Loading...
Loading...
Loading...
Loading...
Loading...
Loading...