Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit

Novus Biologicals, part of Bio-Techne | Catalog # SP-8400-NB

Novus Biologicals, part of Bio-Techne
Catalog #
Availability
Size / Price
Qty
Loading...
SP-8400-NB

Key Product Details

Applications

Functional Assay, Immunohistochemistry

Kit Type

Autofluorescence Quenching Kit

Product Summary for Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit

Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit provides a novel way to remove unwanted fluorescence in tissue sections due to aldehyde fixation, red-blood cells, and structural elements such as collagen and elastin. This unique formulation binds and effectively quenches the autofluorescent elements in even the most problematic tissues, such as kidney, spleen and pancreas. The use of Vector(R) TrueVIEW(TM) leads to significant enhancement in overall signal-to-noise in most immunofluorescence assays.

Product Specifications

Application Notes

One kit is sufficient to treat approximately 100 to 150 tissue sections..

Scientific Data Images for Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit

Immunohistochemistry: Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit [SP-8400-NB]

Immunohistochemistry: Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit [SP-8400-NB]

Immunohistochemistry: Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit [SP-8400-NB] - Pancreas (FFPE), antigen retrieved with Antigen Unmasking Solution, stained with Guinea Pig x Insulin (green) and Mouse x END (red), followed by FL-Goat x Guinea Pig IgG + Dylight(R) 594-Horse x Mouse IgG. Mounted in VECTASHIELD(R) HardSet(TM) Mounting Medium with DAPI.No TrueVIEW(TM) Quencher => 20x objective, red channel exposed 600ms, green channel 600ms.With TrueVIEW(TM) Quencher => 20x objective, red channel exposed 600ms, green channel exposed 600ms.
Immunohistochemistry: Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit [SP-8400-NB]

Immunohistochemistry: Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit [SP-8400-NB]

Immunohistochemistry: Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit [SP-8400-NB] - Spleen (FFPE), antigen retrieved with Antigen Unmasking Solution, stained using Mouse Anti-CD20 (red) and Rabbit Anti-Ki67 (green), followed by VectaFluor(TM) Duet Kit, and mounted in VECTASHIELD(R) HardSet(TM) Mounting Medium with DAPI. Left: No TrueVIEW(TM) Quencher treatment - note interfereing autofluorescence. Right: Treated with TrueVIEW(TM) Autofluorescence Quencher.No TrueVIEW(TM) Quencher => 20x objective, red channel exposed 200ms, green channel 200ms.With TrueVIEW(TM) Quencher => 20x objective, red channel exposed 200ms, green channel exposed 800ms.

Kit Contents for Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit

  • 2 ml VECTASHIELD(R) HardSet(TM) Antifade Mounting Medium
  • 5 ml Vector(R) TrueVIEW(TM) Reagent A
  • 5 ml Vector(R) TrueVIEW(TM) Reagent B
  • 5 ml Vector(R) TrueVIEW(TM) Reagent C

Formulation, Preparation, and Storage

Concentration

Concentration is not relevant for this product. Please see the protocols for proper use of this product.

Shipping

The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below.

Storage

Store at 4C in the dark.

Background: Vector(R) TrueVIEW(TM)

Tissue autofluorescence often occurs with aldehyde fixation or from inherent native tissue components (collagen, elastin, and red blood cells). The extent and intensity of autofluorescence background frequently makes it difficult or impossible to distinguish specific signals in immunofluorescence applications. Most methods for reduction of tissue autofluorescence act primarily on lipofuscin granules, and are not broadly effective against the most common sources of autofluorescence targeted by Vector(R) TrueVIEW(TM) Quencher. The Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit provides a novel way to diminish unwanted autofluorescence from non-lipofuscin sources and dramatically improve signal-to-noise ratio. The quenching action of the kit reagents provides a clear, unambiguous, true view localization of the target antigen. Current methods for reducing autofluorescence primarily include home brew concoctions such as sodium borohydride and other ink-based products. These methods are essentially ineffective against aldehyde induced autofluorescence. In contrast, Vector(R) TrueVIEW(TM) reagent binds to hydrophilic compounds and effectively quenches endogenous autofluorescence.

Additional Vector(R) TrueVIEW(TM) Products

Product Documents for Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Product Specific Notices for Vector(R) TrueVIEW(TM) Autofluorescence Quenching Kit

This product is manufactured by Vector Laboratories and distributed by Novus Biologicals.

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Kits are guaranteed for 6 months from date of receipt.