Skip to main content

Key Product Details

Species Reactivity

Rat

Applications

ELISA Standard (Matched Pair), ELISA Capture (Matched Antibody Pair), ELISA Detection (Matched Antibody Pair)

Label

CoraFluor 1

Antibody Source

Monoclonal Mouse IgG2A Clone # 233539

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Product Specifications

Immunogen

Mouse myeloma cell line NS0-derived recombinant rat C‑Reactive Protein/CRP
His20-Ser230
Accession # P48199

Specificity

Detects rat C‑Reactive Protein/CRP in direct ELISAs. In sandwich immunoassays, no cross-reactivity with recombinant mouse CRP, recombinant porcine CRP, recombinant human (rh) Pentraxin 2, or rhPentraxin 3 is observed.

Clonality

Monoclonal

Host

Mouse

Isotype

IgG2A

Description

CoraFluor(TM) 1 is a high performance terbium-based TR-FRET (Time-Resolved Fluorescence Resonance Energy Transfer) or TRF (Time-Resolved Fluorescence) donor for high throughput assay development. CoraFluor(TM) 1 absorbs UV light at approximately 340 nm, and emits at approximately 490 nm, 545 nm, 585 nm and 620 nm. It is compatible with common acceptor dyes that absorb at the emission wavelengths of CoraFluor(TM) 1. CoraFluor(TM) 1 can be used for the development of robust and scalable TR-FRET binding assays such as target engagement, ternary complex, protein-protein interaction and protein quantification assays.

CoraFluor(TM) 1, amine reactive

CoraFluor(TM) 1, thiol reactive

For more information, please see our CoraFluor(TM) TR-FRET technology flyer.

Scientific Data Images for C-Reactive Protein/CRP Antibody (233539) [CoraFluor™ 1]

C-Reactive Protein/CRP Antibody (233539) [CoraFluor™ 1]

Product Feature: CoraFluor Probes for TR-FRET

CoraFluor™ 1, amine reactive (Catalog:7920) and CoraFluor™ 2, amine reactive (Catalog # 7950) are terbium-based probes that have been developed for use as TR-FRET donors. They emit wavelengths compatible with commonly used fluorescent acceptor dyes such as BODIPY® (or BDY) and Janelia Fluor® dyes, FITC (Catalog # 5440), TMR and Cyanine 5 (Catalog # 5436). CoraFluor™ fluorescence is brighter and more stable in biological media than existing TR-FRET donors, leading to enhanced sensitivity and improved data generation. CoraFluor™ 1 exhibits excitation upon exposure to a 337 nm UV laser.

Applications for C-Reactive Protein/CRP Antibody (233539) [CoraFluor™ 1]

Application
Recommended Usage

ELISA Capture (Matched Antibody Pair)

Optimal dilutions of this antibody should be experimentally determined.

ELISA Detection (Matched Antibody Pair)

Optimal dilutions of this antibody should be experimentally determined.

ELISA Standard (Matched Pair)

Optimal dilutions of this antibody should be experimentally determined.
Application Notes
Optimal dilution of this antibody should be experimentally determined.

Formulation, Preparation, and Storage

Purification

Protein A or G purified from hybridoma culture supernatant

Formulation

PBS

Preservative

No Preservative

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store at 4C in the dark. Do not freeze.

Background: C-Reactive Protein/CRP

C Reactive Protein is a major acute phase reactant synthesized primarily in the liver hepatocytes. It is a pentraxin (cyclic pentameric protein) compound of five identical nonglycosylated subunits of 206 amino acids each (m.w. 24 kDa), that are bound noncovalently to form the physiologic CRP molecule (m.w. 117.5 kDa). C Reactive Protein mediates activities associated with preimmune nonspecific host resistance. It is opsonic, an initiator of the classical complement cascade and an activator of monocytes/macrophages. CRP also binds to several nuclear components including chromatin, histones and snRNP, suggesting that it may play a role as a scavenger during cell necrosis. Studies have revealed that among other markers of inflammation, CRP shows the strongest association with cardiovascular events. Many clinical studies demonstrated that coronary mortality among patients with unstable angina and elevated CRP is significantly higher comparing with the patients without elevated CRP. Measurements of C reactive protein (hsCRP) in the patients with ischemic heart disease provide a novel method for detecting individuals at high risk of plaque rupture.

Alternate Names

CRP

Gene Symbol

CRP

Additional C-Reactive Protein/CRP Products

Product Documents for C-Reactive Protein/CRP Antibody (233539) [CoraFluor™ 1]

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Product Specific Notices for C-Reactive Protein/CRP Antibody (233539) [CoraFluor™ 1]

CoraFluor (TM) is a trademark of Bio-Techne Corp. Sold for research purposes only under agreement from Massachusetts General Hospital. US patent 2022/0025254

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.

Loading...
Loading...
Loading...
Loading...