Simple Plex Human DcR3 Cartridge
ProteinSimple, part of Bio-Techne | Catalog # SPCKB-PS-000876
Customize Your Simple Plex Cartridge
Simple Plex cartridges are custom built to fit your needs. Choose from over 350 assays spanning human, mouse, rat, and non-human primate. Just select your sample type, cartridge size (16, 32, or 72 samples), and add up to 8 analytes per cartridge.
Key Product Details
Assay Length
Sample Type & Volume Required Per Well*
Sensitivity
Assay Range
Simple Plex Human DcR3 Cartridge Summary
*The Sample Volume represented is based on the amount of sample incorporated into the reaction after taking into account the assay's minimum required dilution for a given matrix. Serial dilution may be necessary to achieve some of the final sample volumes represented.
Compatible Instruments
Ella Automated Immunoassay System
Product Specifications
Assay Type
Format
Reactivity
Specificity
Cross-reactivity
Interference
Precision
Intra-Assay Precision (Precision within an assay) Each control was tested multiple times in one DcR3 assay.
Inter-Assay Precision (Precision between assays) Replicates of each DcR3 control were tested in multiple assays performed by at least three technicians using two lots of reagents for human DcR3.
EDTA Plasma, Heparin Plasma, Serum
| Intra-Assay Precision | Inter-Assay Precision | |||
|---|---|---|---|---|
| Sample | 1 | 2 | 1 | 2 |
| n | 16 | 16 | 57 | 56 |
| Mean (pg/mL) | 116 | 4714 | 114 | 5031 |
| Standard Deviation | 6.78 | 375 | 11.6 | 473 |
| CV% | 5.8 | 8.0 | 10.3 | 9.4 |
Recovery for Simple Plex Human DcR3 Cartridge
Recovery was not necessary as human DcR3 shows 5 points of natural linearity.
Linearity
Samples containing and/or spiked with high concentrations of human DcR3 were serially diluted with Sample Diluent to produce samples within the dynamic range of the assay
Scientific Data Images for Simple Plex Human DcR3 Cartridge
Simple Plex Human DcR3 Assay Standard Curve
Data shown represents typical performance results for Lower Limit of Quantitation (LLOQ) and Upper Limit of Quantitation (ULOQ) for Simple Plex Human DcR3 Assay. Assay range is 10.5-16,000 pg/mL.Preparation and Storage
Shipping
Stability & Storage
Background: DcR3/TNFRSF6B
Decoy receptor 3 (DcR3), also called TNFRSF6B, TR6 and M68, is a member of the TNF receptor superfamily. DcR3 lacks a transmembrane sequence and is a secreted protein. DcR3 shares sequence identity with OPG (31%), TNF RII (29%) and Fas (17%), and is expressed in a variety of different tissues and at high levels in many malignant tumors.
Long Name
Alternate Names
Gene Symbol
Additional DcR3/TNFRSF6B Products
Product Documents for Simple Plex Human DcR3 Cartridge
Product Specific Notices for Simple Plex Human DcR3 Cartridge