Simple Plex Human CCL16/HCC-4 Cartridge
ProteinSimple, part of Bio-Techne | Catalog # SPCKB-PS-000336
Customize Your Simple Plex Cartridge
Simple Plex cartridges are custom built to fit your needs. Choose from over 350 assays spanning human, mouse, rat, and non-human primate. Just select your sample type, cartridge size (16, 32, or 72 samples), and add up to 8 analytes per cartridge.
Key Product Details
Assay Length
Sample Type & Volume Required Per Well*
Sensitivity
Assay Range
Simple Plex Human CCL16/HCC-4 Cartridge Summary
*The Sample Volume represented is based on the amount of sample incorporated into the reaction after taking into account the assay's minimum required dilution for a given matrix. Serial dilution may be necessary to achieve some of the final sample volumes represented.
Compatible Instruments
Ella Automated Immunoassay System
Product Specifications
Assay Type
Format
Reactivity
Specificity
Cross-reactivity
Interference
Precision
Intra-Assay Precision (Precision within an assay) Each control was tested multiple times in one HCC-4 assay.
Inter-Assay Precision (Precision between assays) Replicates of each HCC-4 control were tested in multiple assays performed by at least three technicians using two lots of reagents for human HCC-4.
EDTA Plasma, Heparin Plasma, Serum
| Intra-Assay Precision | Inter-Assay Precision | |||
|---|---|---|---|---|
| Sample | 1 | 2 | 1 | 2 |
| n | 16 | 16 | 19 | 18 |
| Mean (pg/mL) | 81.9 | 3709 | 91.3 | 4117 |
| Standard Deviation | 5.27 | 252 | 9.86 | 538 |
| CV% | 6.4 | 6.8 | 10.8 | 13.1 |
Recovery for Simple Plex Human CCL16/HCC-4 Cartridge
Recovery was not necessary as human HCC-4 shows 5 points of natural linearity.
Linearity
Samples containing and/or spiked with high concentrations of human HCC-4 were serially diluted with Sample Diluent to produce samples within the dynamic range of the assay
Scientific Data Images for Simple Plex Human CCL16/HCC-4 Cartridge
Simple Plex Human HCC-4 Assay Standard Curve
Data shown represents typical performance results for Lower Limit of Quantitation (LLOQ) and Upper Limit of Quantitation (ULOQ) for Simple Plex Human HCC-4 Assay. Assay range is 7.86-12,000 pg/mL.Preparation and Storage
Shipping
Stability & Storage
Background: CCL16/HCC-4
Human HCC-4, also named NCC-4, liver-expressed chemokine (LEC), and lymphocyte and monocyte chemoattractant (LMC), is a novel CC chemokine identified through bioinformatics. HCC-4 is distantly related to other CC chemokines, exhibiting less than 30% sequence identity. Among these CC chemokines, HCC-4 has the most similarity to HCC-1.
Additional CCL16/HCC-4 Products
Product Documents for Simple Plex Human CCL16/HCC-4 Cartridge
Product Specific Notices for Simple Plex Human CCL16/HCC-4 Cartridge
For research use only