Jess™ protein reagents and consumables from ProteinSimple, a Bio-Techne brand, are designed for use with ProteinSimple's Jess, a Simple Western™ platform, and must be used in conjunction with Compass Software version 2.5 or higher and compatible firmware. Simple Western assays on Jess using RePlex™ reduce reagent and consumable costs.
Help scientists and fund you research. Submit new antibody validation data to the Simple Western antibody database and receive a free 8x25 separation module or detection module! Learn more about this offer at Simple Western Antibody Submission Promotion.
Assay Modules
Part # | Description |
---|---|
DM-PN02 |
Protein Normalization Module Compatible with Jess™ systems ONLY. Includes 8x Protein Normalization Reagent and Protein Normalization Reconstitution Agent. Must be used with Fluorescence Separation Module - sold separately. |
DM-001 |
Anti-Rabbit Detection Module Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Module includes: Luminol-S, Peroxide, Antibody Diluent 2, Anti-Rabbit Secondary Antibody, Streptavidin-HRP. |
DM-002 |
Anti-Mouse Detection Module Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Module includes: Luminol-S, Peroxide, Antibody Diluent 2, Anti-Mouse Secondary Antibody, Streptavidin-HRP. |
DM-003 |
No secondary Detection Module Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Module includes: Luminol-S, Peroxide, Antibody Diluent 2, Streptavidin-HRP. |
DM-004 |
Biotin Detection Module Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Module includes: Secondary Streptavidin HRP, Luminol-S, Peroxide, Antibody Diluent 2, and Streptavidin-HRP (for biotinylated ladder). Compatible with Separation module - sold separately. |
DM-005 |
Anti-Human IgG Detection Module Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Module includes: Anti-Human IgG Secondary HRP Antibody, Luminol-S, Peroxide, Antibody Diluent 2, and Streptavidin-HRP. Compatible with Separation module - sold separately. |
DM-006 |
Anti-Goat Detection Module Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Module includes: Anti-Goat Secondary HRP Antibody, Luminol-S, Peroxide, Milk-free Antibody Diluent (use to dilute goat primary antibody and as blocking agent), and Streptavidin-HRP. Compatible with Separation module - sold separately. |
DM-007 |
Anti-Rabbit NIR Detection Module Compatible with Jess™ systems ONLY. Module includes: Anti-Rabbit NIR Secondary Antibody, Milk-Free Diluent and Streptavidin-NIR. Must be used with Fluorescence Separation module - sold separately. |
DM-008 |
Anti-Rabbit IR Detection Module Compatible with Jess™ systems ONLY. Module includes: Anti-Rabbit IR Secondary Antibody, Milk-Free Diluent and Streptavidin-NIR. Must be used with Fluorescence Separation module - sold separately. |
DM-009 |
Anti-Mouse NIR Detection Module Compatible with Jess™ systems ONLY. Module includes: Anti-Mouse NIR Secondary Antibody, Milk-Free Diluent and Streptavidin-NIR. Must be used with Fluorescence Separation module - sold separately. |
DM-010 |
Anti-Mouse IR Detection Module Compatible with Jess™ systems ONLY. Module includes: Anti-Mouse IR Secondary Antibody, Milk-Free Diluent and Streptavidin-NIR. Must be used with Fluorescence Separation module - sold separately. |
DM-013 |
Anti-Rabbit Stellar IR Detection Module Compatible with Jess™ systems ONLY. Module includes: Stellar Anti-Rabbit Secondary Antibody, Stellar Rabbit IR, Stellar Rabbit IR Anneal, Stellar IR Label, Antibody Diluent 1, Antibody Diluent 2, Streptavidin-NIR, Stellar Hybridization Buffer, and Stellar Wash Buffer. Must be used with Fluorescence Separation module - sold separately. |
DM-014 |
Anti-Rabbit Stellar NIR Detection Module Compatible with Jess™ systems ONLY. Module includes: Stellar Anti-Rabbit Secondary Antibody, Stellar Rabbit NIR Oligo, Stellar NIR Anneal, Stellar NIR Label, Antibody Diluent 1, Antibody Diluent 2, Streptavidin-NIR, Stellar Hybridization Buffer, and Stellar Wash Buffer. Must be used with Fluorescence Separation module - sold separately. |
DM-015 |
Anti-Mouse Stellar IR Detection Module Compatible with Jess™ systems ONLY. Module includes: Stellar Anti-Mouse Secondary Antibody, Stellar Mouse IR, Stellar Mouse IR Anneal, Stellar IR Label, Antibody Diluent 1, Antibody Diluent 2, Streptavidin-NIR, Stellar Hybridization Buffer, and Stellar Wash Buffer. Must be used with Fluorescence Separation module - sold separately. |
DM-016 |
Anti-Mouse Stellar NIR Detection Module Compatible with Jess™ systems ONLY. Module includes: Stellar Anti-Mouse Secondary Antibody, Stellar Mouse NIR Oligo, Stellar NIR Anneal, Stellar NIR Label, Antibody Diluent 1, Antibody Diluent 2, Streptavidin-NIR, Stellar Hybridization Buffer, and Stellar Wash Buffer. Must be used with Fluorescence Separation module - sold separately. |
DM-TP01 |
Total Protein Detection Module for Chemiluminescence Based Total Protein Assays Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. The Total protein detection module for Chemiluminescence based total protein assays includes Luminol-S, Peroxide, Antibody Diluent 2, Total Protein Reconstitution Agent 2, Total Protein Streptavidin-HRP. Compatible with Separation module - sold separately. |
DM-TP03 |
Stellar Total Protein Detection Module Compatible with Jess™ systems ONLY. The Stellar Total Protein Detection Module for Chemiluminescence based total protein assays includes Luminol (2 x 2 mL), Peroxide (2 x 2 mL), Stellar Total Protein Streptavidin-HRP, Total Protein Reconstitution Agent 2, 8x Biotin Labeling Reagent plus 1x Total Protein, and Reconstitution Agent 1. Must be used with Fluorescence Separation Module - sold separately. |
SM-FL001 |
12-230 kDa Fluorescence Separation Module, 8 x 13 capillary cartridges Compatible with Jess™ systems. Includes separation box with Fluorescent Capillary Cartridges, 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x13 fluorescent capillaries per cartridge (104 data points). |
SM-FL002 |
66-440 kDa Fluorescence Separation Module, 8 x 13 capillary cartridges Compatible with Jess™ systems. Includes separation box with Fluorescent Capillary Cartridges, 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 5 clamshell with DTT, FL Standard master mix with 90 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x13 fluorescent capillaries per cartridge (104 data points). |
SM-FL003 |
2-40 kDa Fluorescence Separation Module, 8 x 13 capillary cartridges Compatible with Jess™ systems. Includes separation box with Fluorescent Capillary Cartridges, 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 3 clamshell with DTT, FL Standard master mix with 26 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x13 fluorescent capillaries per cartridge (104 data points). |
SM-FL004 |
12-230 kDa Fluorescence Separation Module, 8 x 25 capillary cartridges Compatible with Jess™ systems. Includes separation box with Fluorescent Capillary Cartridges, 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x25 fluorescent capillaries per cartridge (200 data points). |
SM-FL005 |
66-440 kDa Fluorescence Separation Module, 8 x 25 capillary cartridges Compatible with Jess™ systems. Includes separation box with Fluorescent Capillary Cartridges, 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 5 clamshell with DTT, FL Standard master mix with 90 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x25 fluorescent capillaries per cartridge (200 data points). |
SM-FL006 |
2-40 kDa Fluorescence Separation Module, 8 x 25 capillary cartridges Compatible with Jess™ systems. Includes separation box with Fluorescent Capillary Cartridges, 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 3 clamshell with DTT, FL Standard master mix with 26 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x25 fluorescent capillaries per cartridge (200 data points). |
SM-W001 |
12-230 kDa Separation Module, 2 x 13 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems. Includes separation box with Capillary Cartridges, 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 2x13 capillaries per cartridge (26 data points). |
SM-W002 |
12-230 kDa Separation Module, 8 x 13 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems. Includes separation box with Capillary Cartridges, 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x13 capillaries per cartridge (104 data points). |
SM-W003 |
12-230 kDa Separation Module, 2 x 25 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems. Includes separation box with Capillary Cartridges, 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 2x25 capillaries per cartridge (50 data points). |
SM-W004 |
12-230 kDa Separation Module, 8 x 25 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems. Includes separation box with Capillary Cartridges, 12-230 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately.Sizing: 8x25 capillaries per cartridge (200 data points). |
SM-W005 |
66-440 kDa Separation Module, 2 x 13 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems. Includes separation box with Capillary Cartridges, 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 2x13 capillaries per cartridge (26 data points). |
SM-W006 |
66-440 kDa Separation Module, 8 x 13 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems. Includes separation box with Capillary Cartridges, 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x13 capillaries per cartridge (104 data points). |
SM-W007 |
66-440 kDa Separation Module, 2 x 25 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems. Includes separation box with Capillary Cartridges, 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 2x25 capillaries per cartridge (50 data points). |
SM-W008 |
66-440 kDa Separation Module, 8 x 25 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems. Includes separation box with Capillary Cartridges, 66-440 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x25 capillaries per cartridge (200 data points). |
SM-W009 |
2-40 kDa Separation Module, 2 x 13 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems using Compass v3.0 or higher. Includes separation box with Capillary Cartridges, 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 2x13 capillaries per cartridge (26 data points). |
SM-W010 |
2-40 kDa Separation Module, 8 x 13 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems using Compass v3.0 or higher. Includes separation box with Capillary Cartridges, 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x13 capillaries per cartridge (104 data points). |
SM-W011 |
2-40 kDa Separation Module, 2 x 25 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems using Compass v3.0 or higher. Includes separation box with Capillary Cartridges, 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 2x25 capillaries per cartridge (50 data points). |
SM-W012 |
2-40 kDa Separation Module, 8 x 25 capillary cartridges Compatible with Jess™, Abby™ and Wes™ systems using Compass v3.0 or higher. Includes separation box with Capillary Cartridges, 2-40 kDa Pre-filled Plates (pre-filled with Separation Matrix 2, Stacking Matrix 2, Split Running Buffer 2 and Matrix Removal Buffer), Sample Buffer, Wash Buffer, plus Standard Pack 1 clamshell with DTT, FL Standard master mix with 29 kDa System Control protein. Compatible with Detection module - sold separately. Sizing: 8x25 capillaries per cartridge (200 data points). |
PS-T001 |
Chemiluminescence Training Kit Compatible with Jess™, Abby™, and Wes™ systems. Includes a 12-230 kDa Separation Module (SM-W004), Anti-Rabbit Detection Module (DM-001), 10X System Control Primary Antibody, ERK1 Primary Antibody, Anti-Mouse Secondary Antibody, and HeLa Lysate Control for Size. |
PS-T004 |
Fluorescence Training Kit Compatible with Jess™ systems. Includes a 12-230 kDa Separation Module (SM-W004), Anti-Rabbit Secondary IR Antibody, Milk-Free Antibody Diluent, Streptavidin-NIR, Anti-Mouse Secondary NIR Antibody, Reconstitution Reagent 2, HeLa Lysate Control for Size, β-Actin Primary Antibody, and HSP60 Primary Antibody. |
PS-T005 |
Chemiluminescence and Fluorescence Training Kit Compatible with Jess™ systems. Includes a 12-230 kDa Separation Module (SM-W004), Anti-Rabbit Secondary IR Antibody, Milk-Free Antibody Diluent, Streptavidin-NIR, Anti-Mouse Secondary NIR Antibody, Reconstitution Reagent 2, HeLa Lysate Control for Size, β-Actin Primary Antibody, HSP60 Primary Antibody, Anti-Rabbit HRP Detection Module (DM-001), 10X System Control Primary Antibody, ERK1 Primary Antibody, and Anti-Mouse HRP Secondary Antibody. |
PS-T007 |
Stellar Training Kit Compatible with Jess™ systems. Includes a 12-230kDa Fluorescence Separation Module (SM-FL004), Anti-Rabbit Stellar IR Detection Module (DM-013), β-tubulin Primary Antibody, HeLa Lysate Control for Size, and SimplePrep for Stellar. |
RP-001 |
RePlex™ Module Compatible with Jess™ and Abby™ systems ONLY. The RePlex Module provides all the reagents needed to remove primary and secondary antibodies in a RePlex assay with two immunoassays or immunoassay with Total Protein assay in a single run. |
SA-001 |
SARS-CoV2 Multi-Antigen Serology Module Compatible with Jess™, Abby™ and Wes™ systems. The SARS-CoV-2 Multi-Antigen Serology Module provides all the reagents needed to detect SARS-CoV-2 IgG antibodies in human serum or plasma in a Simple Western size-based assay when paired with a Separation Module. Please note that this module is for research use only. |
Individual Reagents
Part # | Description |
---|---|
PS-ST05EZ-8 |
EZ Standard Pack 5 Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Pack includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 2-40 kDa) and Single Use FL Standard (26 kDa system control protein) vials. Pack contains enough reagents to obtain 200 Simple Western data points. |
PS-ST04EZ-8 |
EZ Standard Pack 4 Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Pack includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 66-440 kDa) and Single Use FL Standard (200 kDa system control protein) vials. Pack contains enough reagents to obtain 200 Simple Western data points. |
PS-ST03EZ-8 |
EZ Standard Pack 3 Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Pack includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 66-440 kDa) and Single Use FL Standard (90 kDa system control protein) vials. Pack contains enough reagents to obtain 200 Simple Western data points. |
PS-ST02EZ-8 |
EZ Standard Pack 2 Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Pack includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 12-230 kDa) and Single Use FL Standard (180 kDa system control protein) vials. Pack contains enough reagents to obtain 200 Simple Western data points. |
PS-ST01EZ-8 |
EZ Standard Pack 1 Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Pack includes 8 packets with one each of the Single Use Biotinylated Ladder (MW ladder spans 12-230 kDa) and Single Use FL Standard (29 kDa system control protein) vials. Pack contains enough reagents to obtain 200 Simple Western data points. |
PS-FL01-8 |
Fluorescent 5x Master Mix 1 Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Pack includes 8 packets with one each of the Single Use FL Standard (29 kDa system control protein) and Single Use DTT vials. Compatible with 12-230 Separation Modules - sold separately. |
PS-FL03-8 |
Fluorescent 5x Master Mix 3 Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Pack includes 8 packets with one each of the Single Use FL Standard (90 kDa system control protein) and Single Use DTT vials. Compatible with 66-440 kD Separation Modules - sold separately. |
PS-FL05-8 |
Fluorescent 5x Master Mix 5 Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Pack includes 8 packets with one each of the Single Use FL Standard (26 kDa system control protein) and Single Use DTT vials. Compatible with 2-40 kD Separation Modules - sold separately. |
042-976 |
Total Protein Streptavidin-HRP Use with Compass v2.6 or higher. Streptavidin-HRP for Total Protein Assay Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems., 2.0 mL. Ready to use. |
042-414 |
Streptavidin-HRP Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. Streptavidin-HRP Conjugate (ready-to-use reagent) for use with the Simple Western Size Standard. |
042-195 |
Sample Buffer Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. |
042-206 |
Anti-Rabbit Secondary Antibody Goat Anti-Rabbit Secondary HRP Conjugate (ready-to-use reagent) for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. |
042-205 |
Anti-Mouse Secondary Antibody Goat Anti-Mouse Secondary HRP Conjugate (ready-to-use reagent) for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. |
043-426 |
20X Anti-Rabbit HRP Conjugate 20X Anti-Rabbit HRP Conjugate, 150 µL for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. To be diluted to 1X with RTU Anti-Mouse Secondary Antibody (042-205) when multiplexing with primary antibodies raised in mouse and rabbit. |
042-203 |
Antibody Diluent 2 Antibody Diluent 2 (20 mL) for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. We strongly recommends use of the Antibody Diluent for dilution of primary and secondary antibodies as it has been proven superior to any other buffer system tested. |
042-196 |
10x System Control Primary Antibody (Rabbit) Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. To be used with rabbit primary antibody to Antibody Diluent. Detects system controls. Match with Standard pack 1, 2, 3 or 4 (250 µl/vial). |
042-191 |
10x System Control Primary Antibody (Mouse) Compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. The 10X System Control Primary Antibody-Mouse detects system controls is to be used with Antibody Diluent. *Please match accordingly with Standard packs 1, 2, 3 or 4 (250 µl/vial). |
042-202 |
Wash Buffer Wash Buffer (60 mL) for use on Jess™, Abby™ and Wes™ systems. |
PS-CS01 |
Chemiluminescent Substrate Compatible with Jess™, Abby™ and Wes™ systems. The chemiluminescent Substrate includes Luminol-S (P/N: 042-233) and Peroxide (P/N: 042-234). Each order contains two bottles of 2.0mL of substrate/bottle. |
042-486 |
ERK 1 Primary Antibody for Size Assays Erk 1 Rabbit Primary Antibody, 1X stock (1 mL) for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. |
042-488 |
HeLa Lysate Controls HeLa lysate, lysed in RIPA Lysis Buffer (20 µL/vial) for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. |
043-311 |
Luminol-S Luminol-S (2 mL) for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. |
043-379 |
Peroxide Peroxide (2 mL) for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. |
043-522-2 |
Anti-Goat Secondary HRP Antibody Donkey Anti-Goat Secondary HRP Conjugate (ready-to-use reagent) for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. ProteinSimple recommends the use of our Milk-free Antibody Diluent (043-524) to dilute goat primary and as a blocking agent. |
043-491-2 |
Anti-Human IgG Secondary HRP Antibody Goat Anti-Human Secondary HRP Conjugate (ready-to-use reagent) for use on Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. |
043-459-2 |
Secondary Streptavidin-HRP Secondary Streptavidin-HRP Conjugate (ready-to-use reagent) for use with a biotinylated antibody in Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. For total protein assay use Secondary Streptavidin-HRP (P/N: 042-976) and to detect biotinylated molecular weight ladders use Streptavidin-HRP (P/N: 042-414). |
043-524 |
Milk-free Antibody Diluent Milk-free Antibody Diluent compatible with Jess™, Abby™, Wes™, Peggy Sue and Sally Sue systems. We recommend its use for dilution of goat primary, anti-goat secondary and as blocking agent as it has been shown to be superior in reducing background compared to other diluents tested. |
043-816 |
Streptavidin-NIR Streptavidin-NIR Conjugate (ready-to-use reagent) for use with the Simple Western Size Standard. Compatible with Jess™ systems ONLY. |
043-819 |
Anti-Rabbit Secondary NIR Antibody 20X Anti-Rabbit Secondary NIR conjugate for use on Jess™ systems ONLY. |
043-820 |
Anti-Rabbit Secondary IR Antibody 20X Anti-Rabbit Secondary IR conjugate for use on Jess™ systems ONLY. |
043-821 |
Anti-Mouse Secondary NIR Antibody 20X Anti-Mouse Secondary NIR conjugate for use on Jess™ systems ONLY. |
043-822 |
Anti-Mouse Secondary IR Antibody 20X Anti-Mouse Secondary IR conjugate for use on Jess™ systems ONLY. |
Consumables
Part # | Description |
---|---|
004-651 |
Blot Membrane holder Compatible with Jess™ systems ONLY. This Blot membrane cartridge can used to image traditional Western blot membranes using chemiluminescence detection. |
PS-PP05 |
2-40 kDa Pre-filled Plates Compatible with Jess™, Abby™ and Wes™ systems using Compass v3.0 or higher. Includes 8 Plates (pre-filled with Separation Matrix, Stacking Matrix, Split Running Buffer and Matrix Removal Buffer). |
PS-PP04 |
66-440 kDa Pre-filled Plates Compatible with Jess™, Abby™ and Wes™ systems using Compass v2.7 or higher. Includes 8 Plates (pre-filled with Separation Matrix, Stacking Matrix, Split Running Buffer 3 and Matrix Removal Buffer). |
PS-PP03 |
12-230 kDa Pre-filled Plates Compatible with Jess™, Abby™ and Wes™ systems using Compass v2.7 or higher. Includes 8 Plates (pre-filled with Separation Matrix, Stacking Matrix, Split Running Buffer 2 and Matrix Removal Buffer). |
PS-CC01 |
25-Capillary cartridges for Size based Separation Compatible with Jess™, Abby™ and Wes™ systems ONLY. Includes 8 pack of capillaries required to perform for size assays. Sizing: 8 cartridges - 25 capillaries/cartridge. |
PS-CC02 |
13-Capillary cartridges for Size based Separation Compatible with Jess™, Abby™ and Wes™ systems ONLY. Includes 8 pack of capillaries required to perform for size assays. Sizing: 8 cartridges - 13 capillaries/cartridge. |