From discovery to clinical research, Simple Plex Ultra-Sensitive Assays simplify biomarker detection while delivering robust, reproducible measurement of low abundant proteins. This advancement enables reliable detection and precise quantification of endogenous biomarkers in plasma and serum samples —without added complexity.

  • Ultra sensitivity – Measure biomarkers at endogenous levels with confidence, enabling earlier insights and more precise decision-making.
  • Built-in standard curves  – Save time and reduce errors with automated standard curves, ensuring consistent, reproducible results across every run.
  • Validated for key sample types  – Get reliable results from the most commonly used sample types including CSF, serum, and plasma so you can focus on discovery without worrying about compatibility or validation.
  • Fast results in under 3 hours – Get actionable data quickly, accelerating your research timelines and improving productivity without sacrificing accuracy. 
Neurodegeneration biomarkers, GFAP, NFL, pTau217 and Amyloid Beta detected with Simple Plex Ultra-Sensitive Assays

High detectability of neurodegeneration biomarkers in healthy plasma, at ultra-low concentrations. Neurodegenerative biomarkers were quantified in plasma samples from healthy donors (age 55+), using the Simple Plex Ultra-Sensitive Assay. The results indicate full detectability and near complete quantifiability of all samples across all assays.

Available Ultra-Sensitive Assays

cartridge collection hero

Simple Plex Ultra-Sensitive Assay Technology

How it Works  

  • Sample is routed through a microfluidic circuitry, with synchronized release of assay reagents.  
  • Sandwich immunoassay occurs within Glass Nano Reactors (GNRs). 

Achieving ultra-sensitive detection

  • Assay parameters and microfluidic protocols were systematically optimized to achieve femtogram-level sensitivity.  
  • The platform’s high precision minimizes variability at the low end of the standard curve, enabling more reliable quantification of low abundance analytes.
Simple Plex cartridges showing how sample is routed through a microfluidic circuitry, with synchronized release of assay reagents

Available Simple Plex Assays Comparison

 Discovery Simple Plex Assays
Early Research Testing 
Simple Plex Assays 
Highly Validated Kits 
Ultra-Sensitive Simple Plex Assays 
Highly validated kits for ultra-sensitive detection 
Recommended WhenLess stringent assay specifications for discovery and early researchPrecise and accurate results with tight performance specifications for regulated environmentsSensitive and accurate results for detection of low-abundant proteins at healthy endogenous levels
Sensitivitysub pg/mlsub pg/mlfg/ml
Assay Run Time75 min75 min155 min
Required Sample Volume≤25 µL≤25 µL≤40 µL
Species (currently available)Human, Mouse, RatHuman, Mouse, Rat, Non-Human PrimateHuman
MultiplexUp to 8Up to 8Up to 4 (limited by available analytes)
Assay Performance Intra-assay: ≤12% 
Inter-assay: ≤12% 

Extensively tested throughout manufacture and validated to ensure long-term consistency

Intra-assay: ≤10% 
Inter-assay: ≤12% 

Extensively tested throughout manufacture and validated to ensure long-term consistency

Intra-assay: ≤10% 
Inter-assay: ≤12% 

PrecisionVerified across 2 manufactured lotsValidated across 3+ manufactured lotsValidated across 3+ manufactured lots
LinearityRange 75-125%  
Verified across 2 manufactured lots
Range 80-120% 
Validated across 3+ manufactured lots 
Range 80-120% 
Validated across 3+ manufactured lots 
RecoveryRange 75-125% 
Verified across 2 manufactured lots
Range 80-120% 
Validated across 3+ manufactured lots 
Range 80-120% 
Validated across 3+ manufactured lots 
Assay ValidationVerified with recombinant proteinsVerified recombinant proteins and natural samplesVerified recombinant proteins and natural samples

Resources

Ultra-Sensitive Neuro Biomarker Detection case study thumbnail

Sensitive Neuro Biomarker Detection

Simple Plex Assays have been extensively validated in numerous studies, demonstrating exceptional sensitivity and precision for detecting low abundance proteins. Fluorescent detection improves sensitivity by 10X and boosts dynamic range up to 5 logs while the fully automated assay workflow delivers results in less than 3 hrs.

Ella biomarker detection brochure thumbnail

Rethink Your Biomarker Detection With Ella

Standard ELISA techniques for detecting protein biomarkers often come up short in terms of sensitivity and reproducibility. Ella automates your assay workflow, delivering accurate and consistent data — without the manual set up common with traditional ELISAs. With Ella’s compact footprint and hands-free workflow, you get accurate data with no manual steps.

Immunoassays for Neuroinflammation product guide thumbnail

Immunoassays for Neuroinflammation

The field of research into neurodegeneration and various neurological disorders is growing rapidly. As the range of treatment options broaden and attention turns to early detection, there arises a demand for improved, non-invasive methods to track neuro biomarkers and neuroinflammatory cytokines. In this guide, you’ll find the optimal assays for your neuroinflammation research.

Related Products

Simple Plex AssaysCatalog NumberSimple Plex AssaysCatalog Number
Simple Plex Ultra Phospho-Tau (T217)SPCKB-PS-015536Simple Plex Ultra NFLSPCKB-PS-015538
Simple Plex Amyloid Beta (aa1-42)SPCKB-PS-015537Simple Plex Ultra GFAPSPCKB-PS-015539
Ella System600-100