HLA G Antibody (G233) [DyLight 755]
Novus Biologicals, part of Bio-Techne | Catalog # NB110-55298IR
 
      Conjugate
              Catalog #
              
            Forumulation
              Catalog #
              
            Key Product Details
Species Reactivity
                  Human
                
                                                                                        Applications
                  CyTOF-ready, ELISA, Flow Cytometry, Immunohistochemistry-Frozen, Immunoprecipitation
                
                                                              Label
            DyLight 755 (Excitation = 754 nm, Emission = 776 nm)
          
        Antibody Source
            Monoclonal Mouse IgG2A Clone # G233
          
        Concentration
            Please see the vial label for concentration. If unlisted please contact technical services.
          
        Product Specifications
Immunogen
                          HLA-A2.1/human beta2-microglobulin double transgenic mice were immunized with murine L cells transfected with both human beta2-microglobulin and HLA G Antibody (G233)
                      
        Specificity
                          This antibody (clone G233) recognizes several isoforms of HLA-G expressed in all populations of extravillous trophoblast (cell columns, interstitial trophoblast, endovascular trophoblast, placental bed giant cells). HLA-G belongs to the nonclassical MHC Class I molecules (MHC Class Ib).  The antibody has been found not to cross-react with any other MHC Class I antigens (HLA-A, -B, -C, -E, -F).
                      
        Clonality
                          Monoclonal
                      
        Host
                          Mouse
                      
        Isotype
                          IgG2A
                      
        Applications for HLA G Antibody (G233) [DyLight 755]
          Application
        
        
          Recommended Usage
        
      CyTOF-ready
                                                Optimal dilutions of this antibody should be experimentally determined.
                                                            
                  ELISA
                                                Optimal dilutions of this antibody should be experimentally determined.
                                                            
                  Flow Cytometry
                                                Optimal dilutions of this antibody should be experimentally determined.
                                                            
                  Immunohistochemistry-Frozen
                                                Optimal dilutions of this antibody should be experimentally determined.
                                                            
                  Immunoprecipitation
                                                Optimal dilutions of this antibody should be experimentally determined.
                                                            
                  
        Application Notes
      
      
        Optimal dilution of this antibody should be experimentally determined.
      
    Formulation, Preparation, and Storage
Purification
                          Protein A purified
                      
        Formulation
                          50mM Sodium Borate
                      
        Preservative
                          0.05% Sodium Azide
                      
        Concentration
                          Please see the vial label for concentration. If unlisted please contact technical services.
                      
        Shipping
                          The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
                      
        Stability & Storage
                          Store at 4C in the dark.
                      
        Background: HLA-G
Discovered in cytotrophoblasts, HLA-G is involved in fetal maternal immune tolerance and some studies have linked its downregulation with severe preeclampsia (3). HLA-G mediated immune suppression works by impeding cell proliferation, differentiation, cytotoxicity, cytokine secretion and chemotaxis; and activation of regulatory cells and MDSCs or M2 type macrophage. HLA-G is constitutively expressed in immune-privileged sites such as pancreatic islets, mesenchymal stem cells (MSCs) and the cornea. Upregulation of HLA-G occurs in pathological states including cancer, allo-transplantations, viral infections, autoimmune and inflammatory diseases (4). In cancer, HLA-G expression is induced by hypoxia and has been correlated with advanced tumor stage, tumor metastasis, and poor therapeutic response and survival. HLA-G is an attractive tumor associated-antigen (TAA) for immunotherapy and is considered a major immune checkpoint (ICP).
References
1. Loustau, M., Anna, F., Drean, R., Lecomte, M., Langlade-Demoyen, P., & Caumartin, J. (2020). HLA-G Neo-Expression on Tumors. Front Immunol, 11:1685. PMID: 32922387
2. Lin A, Yan WH. (2018) Heterogeneity of HLA-G Expression in Cancers: Facing the Challenges. Front Immunol. 9:2164. PMID: 30319626
3. Djurisic S, Hviid TV. (2014) HLA Class Ib Molecules and Immune Cells in Pregnancy and Preeclampsia. Front Immunol. 5:652. PMID: 25566263
4. Lila N, Rouas-Freiss N, Dausset J, Carpentier A, Carosella ED. (2001) Soluble HLA-G protein secreted by allo-specific CD4+ T cells suppresses the allo-proliferative response: a CD4+ T cell regulatory mechanism. Proc Natl Acad Sci U S A. 98(21):12150-12155. PMID: 11572934
Long Name
            Major Histocompatibility Complex, Class I, G
          
        Alternate Names
            HLA G, HLA-6.0, HLAG, MHC Class I Antigen G, MHC-G
          
        Gene Symbol
            HLA-G
          
        Additional HLA-G Products
Product Documents for HLA G Antibody (G233) [DyLight 755]
Product Specific Notices for HLA G Antibody (G233) [DyLight 755]
DyLight (R) is a trademark of Thermo Fisher Scientific Inc. and its subsidiaries.
This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.
    Loading...
  
    Loading...
  
    Loading...
  
    Loading...
  
    Loading...
  
Loading...