Human ST2/IL-33R Antibody
R&D Systems, part of Bio-Techne | Catalog # MAB5232
Scientific images may be resized, cropped, or adjusted for brightness or contrast for presentation purposes. These updates are limited to presentation and do not affect the underlying scientific interpretation of the data. Where available, additional source data may be provided upon request.
Key Product Details
Species Reactivity
Applications
Label
Antibody Source
Product Specifications
Immunogen
Lys19-Phe328
Accession # Q01638
Specificity
Clonality
Host
Isotype
Scientific Data Images for Human ST2/IL-33R Antibody
Detection of ST2/IL-33 R in HEK293 Human Cell Line Transfected with Human ST2/IL-33 R and eGFP by Flow Cytometry.
HEK293 human embryonic kidney cell line transfected with either (A) human ST2/IL-33 R or (B) irrelevant transfectants and eGFP was stained with Rabbit Anti-Human ST2/IL-33 R Monoclonal Antibody (Catalog # MAB5232) followed by Allophycocyanin-conjugated Anti-Rabbit IgG Secondary Antibody (Catalog # F0111). Quadrant markers were set based on control antibody staining (Catalog # MAB1050). View our protocol for Staining Membrane-associated Proteins.Human ST2/IL-33 R ELISA Standard Curve.
Recombinant Human ST2/IL-33 R protein was serially diluted 2-fold and captured by Rabbit Anti-Human ST2/IL-33 R Monoclonal Antibody (Catalog # MAB5232) coated on a Clear Polystyrene Microplate (Catalog # DY990). Mouse Anti-Human ST2/IL-33 R Monoclonal Antibody (Catalog # MAB5231) was biotinylated and incubated with the protein captured on the plate. Detection of the standard curve was achieved by incubating Streptavidin-HRP (Catalog # DY998) followed by Substrate Solution (Catalog # DY999) and stopping the enzymatic reaction with Stop Solution (Catalog # DY994).Applications for Human ST2/IL-33R Antibody
ELISA
This antibody functions as an ELISA capture antibody when paired with Mouse Anti-Human ST2/IL-33 R Monoclonal Antibody (Catalog # MAB5231).
This product is intended for assay development on various assay platforms requiring antibody pairs. We recommend the Human ST2/IL-33 R DuoSet ELISA Kit (Catalog # DY523B-05) for convenient development of a sandwich ELISA or the Human ST2/IL-33 R Quantikine ELISA Kit (Catalog # DST200) for a complete optimized ELISA.
Flow Cytometry
Sample: HEK293 human cell line transfected with human ST2/IL-33 R and eGFP
Formulation, Preparation, and Storage
Purification
Reconstitution
Formulation
Shipping
Stability & Storage
- 12 months from date of receipt, -20 to -70 °C as supplied.
- 1 month, 2 to 8 °C under sterile conditions after reconstitution.
- 6 months, -20 to -70 °C under sterile conditions after reconstitution.
Background: ST2/IL-33R
References
-
Barksby, H.E. et al. (2007) Clin. Exp. Immunol. 149:217.
-
Gadina, M. and C.A. Jefferies (2007) Science STKE 2007:pe31.
-
Tominaga, S. et al. (1992) Biochim. Biophys. Acta 1171:215.
-
Li, H. et al. (2000) Genomics 67:284.
-
Schmitz, J. et al. (2005) Immunity 23:479.
-
Lecart, S. et al. (2002) Eur. J. Immunol. 32:2979.
-
Brint, E.K. et al. (2004) Nat. Immunol. 5:373.
-
Weinberg, E.O. et al. (2002) Circulation 106:2961.
-
Sanada S. et al. (2007) J. Clin. Invest. 117:1538.
-
Palmer, G. et al. (2008) Cytokine 42:358.
-
Chackerian, A.A. et al. (2007) J. Immunol. 179:2551.
-
Allakhverdi, Z. et al. (2007) J. Immunol. 179:2051.
-
Verri Jr., W.A. et al. (2008) Proc. Natl. Acad. Sci. 105:2723.
-
Miller, A.M. et al. (2008) J. Exp. Med. 205:339.
-
Hayakawa, H. et al. (2007) J. Biol. Chem. 282:26369.
Long Name
Alternate Names
Gene Symbol
UniProt
Additional ST2/IL-33R Products
Product Documents for Human ST2/IL-33R Antibody
Product Specific Notices for Human ST2/IL-33R Antibody
For research use only