Skip to main content

HPV16/HPV18 E6 Antibody (HPV16/1295 + HPV18/1297) [CoraFluor™ 1]

Novus Biologicals, part of Bio-Techne | Catalog # NBP3-08500CL1

Novus Biologicals, part of Bio-Techne

Key Product Details

Species Reactivity

Virus

Applications

Immunohistochemistry, Immunohistochemistry-Paraffin, Immunocytochemistry/ Immunofluorescence

Label

CoraFluor 1

Antibody Source

Monoclonal Mouse IgG1 kappa Clone # HPV16/1295 + HPV18/1297

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Product Specifications

Immunogen

HPV18 E6-beta-galactosidase fusion protein

Reactivity Notes

Type 16 of Human Papilloma Virus (HPV-16)

Localization

Nuclear

Clonality

Monoclonal

Host

Mouse

Isotype

IgG1 kappa

Description

CoraFluor(TM) 1 is a high performance terbium-based TR-FRET (Time-Resolved Fluorescence Resonance Energy Transfer) or TRF (Time-Resolved Fluorescence) donor for high throughput assay development. CoraFluor(TM) 1 absorbs UV light at approximately 340 nm, and emits at approximately 490 nm, 545 nm, 585 nm and 620 nm. It is compatible with common acceptor dyes that absorb at the emission wavelengths of CoraFluor(TM) 1. CoraFluor(TM) 1 can be used for the development of robust and scalable TR-FRET binding assays such as target engagement, ternary complex, protein-protein interaction and protein quantification assays.

CoraFluor(TM) 1, amine reactive

CoraFluor(TM) 1, thiol reactive

For more information, please see our CoraFluor(TM) TR-FRET technology flyer.

Scientific Data Images for HPV16/HPV18 E6 Antibody (HPV16/1295 + HPV18/1297) [CoraFluor™ 1]

HPV16/HPV18 E6 Antibody (HPV16/1295 + HPV18/1297) [CoraFluor™ 1]

Product Feature: CoraFluor Probes for TR-FRET

CoraFluor™ 1, amine reactive (Catalog:7920) and CoraFluor™ 2, amine reactive (Catalog # 7950) are terbium-based probes that have been developed for use as TR-FRET donors. They emit wavelengths compatible with commonly used fluorescent acceptor dyes such as BODIPY® (or BDY) and Janelia Fluor® dyes, FITC (Catalog # 5440), TMR and Cyanine 5 (Catalog # 5436). CoraFluor™ fluorescence is brighter and more stable in biological media than existing TR-FRET donors, leading to enhanced sensitivity and improved data generation. CoraFluor™ 1 exhibits excitation upon exposure to a 337 nm UV laser.

Applications for HPV16/HPV18 E6 Antibody (HPV16/1295 + HPV18/1297) [CoraFluor™ 1]

Application
Recommended Usage

Immunocytochemistry/ Immunofluorescence

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry

Optimal dilutions of this antibody should be experimentally determined.

Immunohistochemistry-Paraffin

Optimal dilutions of this antibody should be experimentally determined.
Application Notes
Optimal dilution of this antibody should be experimentally determined.

Formulation, Preparation, and Storage

Purification

Protein A or G purified

Formulation

PBS

Preservative

No Preservative

Concentration

Please see the vial label for concentration. If unlisted please contact technical services.

Shipping

The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.

Stability & Storage

Store at 4C in the dark. Do not freeze.

Background: HPV16/HPV18 E6

Human Papilloma virus (HPV) is responsible for the development of type and tissue specific papilloma in the oral cavity and in the larynx. In the skin papilloma virus can cause different types of warts and in the ano-genital region it is associated with condyloma or carcinoma. HPV types 1, 6 and 11 usually are associated with benign transformations of the tissues, while e.g. HPV types 16, 18 and 31 seem to be responsible for the development of some carcinoma like cervical carcinoma. The role of HPV in non-melanoic tumours of the skin is under discussion. Protein E6 is a Transcriptional transactivator, binding double stranded DNA. It has transforming activity inactivating, with E6-AP ubiquitin-protein ligase, the human TP53/p53 tumor suppressor protein by targeting it for degradation. Clinical relevance: Detection of HPV in cervical smears and biopsies. Uses: Analysis of E6 expression in cell transformation studies.

Alternate Names

E6, Human Papilloma Virus, Human papillomavirus type 16 E6, Human papillomavirus type 18 E6, Protein E6

Additional HPV16/HPV18 E6 Products

Product Documents

Certificate of Analysis

To download a Certificate of Analysis, please enter a lot number in the search box below.

Product Specific Notices for HPV16/HPV18 E6 Antibody (HPV16/1295 + HPV18/1297) [CoraFluor™ 1]

CoraFluor (TM) is a trademark of Bio-Techne Corp. Sold for research purposes only under agreement from Massachusetts General Hospital. US patent 2022/0025254

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Primary Antibodies are guaranteed for 1 year from date of receipt.

Loading...
Loading...
Loading...
Loading...